WiseAir – Room Cooling DX Type

Precision cooling for high-density IT environments in Saudi Arabia

The WiseAir Room Cooling DX Type is purpose-built for mission-critical applications in data centers, telecom facilities, and server rooms across Saudi Arabia. 

With inverter-driven compressors and intelligent control architecture, it ensures precise thermal regulation and high system reliability, delivering a stable environment for sensitive IT infrastructure. The Room Cooling DX solution integrates inverter compressors and EC fans with smart control systems that actively regulate temperature based on load conditions. 

This product line offers multiple cooling configurations, including DX air-cooling, DX water-cooling, and chilled water cooling. For more customized deployments, hybrid dual-fluid systems are also available, tailored precisely to project-specific requirements.

Product Features

  • Controlled Energy Consumption: What sets the Room Cooling DX apart for Saudi applications is its indirect free cooling based on refrigerant pump technology. Using a closed refrigerant loop and a built-in refrigerant pump, the system can circulate refrigerant without activating the compressor. This significantly reduces energy consumption while maintaining optimal cooling.
  • Advanced Smart Control System: Equipped with intelligent monitoring, the system features over 1,000 alarm records and stores 7-day historical pressure and temperature data. It supports a wide range of smart protocols, including Web, SNMP, Modbus, Bacnet, Email alerts, dry contacts, and IPv6, enabling seamless integration into modern data center infrastructure.
  • Teamwork Function & Remote Access: The system supports collaborative operation via master/slave working modes, master control mode, and force working mode. With a built-in web server, users can access and control the unit remotely from any computer or mobile device using a standard web browser.
  • Zero-Water Operation & Low Maintenance: In free cooling mode, the system consumes no water and introduces no water loop into the server room. This eliminates the risks of flooding. Its indirect cooling design avoids dust and moisture intrusion. It supports automatic mode switching without the need for complex maintenance routines.
  • Flexible Fan Sinking Design: Optimized for Saudi data center layouts, the system offers a fan sinking design for downflow air conduction. This reduces space requirements during transport and installation. When the fan is positioned beneath a raised floor, it enhances the unit’s energy efficiency ratio, further improving operational performance.

Product Specifications

Inverter compressor Stable temperature control per heating load by adjusting compressor output. 
Humidifier type  Electrode 
PUE  Low to 1.2
Filter rating  G3/G4
Heating capacity 3 – 12 kW
Cooling capacity 5.5 kW – 122.9 kW
Inverter compressor adjustable capacity 30% – 100% 
Refrigerant R410A, no ODP effect
EC fan Highest efficiency with 0-100% speed adjustable
Air flow distribution W Shape evaporator coil for optimized and even airflow distribution
Electronic expansion value Automatic modulating refrigerant flow per system requirement 
Air filters Directly covers the coils to minimize wind resistance and improve efficiency